Pump-solutions-group Neptune Series 560 dia-PUMP Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Pumpen Pump-solutions-group Neptune Series 560 dia-PUMP herunter. Pump Solutions Group Neptune Series 560 dia-PUMP User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - INSTRUCTION

ZL105645 OPERATING & INSTRUCTION MANUAL for NEPTUNE SERIES 560 “dia-PUMPS” Tel.: 215-69

Seite 2 - SAFETY INSTRUCTIONS:

6 2.0 SUCTION PIPING 2.0.1 The suction piping to the pump must be absolutely air tight. It is suggested that the suction piping be tested with low

Seite 3 - WARNING

7 4.0.2 To reset the relief valve to a higher pressure, instructions are as follows: 4.0.21 Connect a test set-up as shown in Figure IV below. 4.

Seite 4 - TABLE OF CONTENTS

8 5.0 INSTALLATION OUTDOORS The “dia-pump” is a totally enclosed pump which can be used outdoors or indoors. When installed outdoors, make sure that

Seite 5 - INTEGRAL TEFC MOTOR

9 SECTION III NORMAL MAINTENANCE 9.0 MAINTENANCE Under normal conditions, the “dia-Pump”does not require any significant amount of maintenance.

Seite 6 - RETURN GOODS AUTHORIZATION

10 11.0.0 PROCEDURE FOR REPLACING CONTROL ROD “O” RING (fig. #2334) AND SEALING PLATE “O” RING (FIG. #516-C on Page#18). 11.0.1 Remove hydraulic fl

Seite 7

11 12.3.0 Start-up instructions after replacing diaphragm. 12.3.1 Fill gearbox with oil (leaving 1/4" - 1/2" inches of air space). Using

Seite 8 - GENERAL

12 SECTION V TROUBLE SHOOTING CHART Symptom Cause Remedy 1. Pump Motor Will Not Operate. A. Blown Fuse. Check for short circuit or overload. B.

Seite 9 - FIGURE 1

13 Symptom Cause Remedy *3. Pump delivers erratically. A. Leaky suction line. Repair or replace piping. B. Worn or dirty valves seats, o

Seite 10 - DISCHARGE PIPING

14 * Silicone Sealant may be substituted for Gasket “N” indicates parts per new version Valve stacks of all Series 5

Seite 11 - FIGURE IV

15 15.0.1 PARTS LIST FOR SERIES.560 "dia-PUMP" FOR OLD STYLE PVC HEAD Pump Serial Number < or = 147994 FOR NEW STYLE PVC HEAD REFFE

Seite 12 - INSTALLATION OUTDOORS

WARNING LOCKOUTS ARE REQUIRED BEFORE SERVICING THIS EQUIPMENT. READ INSTRUCTION SERVICE MANUALS FOR DETAILS.

Seite 13

16 15.0.2 RECOMMENDED SPARE PARTS: IMPORTANT: When ordering spare parts, please show MODEL NUMBER AND SERIAL NUMBER of pump for which parts are bein

Seite 14

17 15.0.4 PARTS FOR "dia..PUMP" ORDERED WITH OTHER THAN STANDARD INTEGRALLY MOUNTED MOTOR (REFER TO DRAWING #000911 on page#19) The fol

Seite 15

18 Drawing 5670SERIES 560 "dia PUMP"SECTION VII DRAWINGS

Seite 16 - TROUBLE SHOOTING CHART

19 DRAWING # FALP DRAWING # 000911 NEWOLD

Seite 17

20 PVC AND KYNAR HEAD OPTION This sheet describes the parts, which are unique to the 560 pumps with the PVC and Kynar Heads. Item No. Descrip

Seite 18

21 APPENDIX ADDENDUM: Special instructions for Series 500, 500-A & 560 “dia-Pumps” with Double Diaphragm THEORY OF OPERATION VACUUM AIR FRO

Seite 19 - PARTS ORDERING INSTRUCTIONS

22 APPENDIX ADDENDUM: Special instructions for Series 500, 500-A & 560 “dia-Pumps” with Double Diaphragm 1.0.8 Close valve Item No. 5 1.0

Seite 20

MATERIAL SAFETY DATA SHEET Page 1 of 4 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Seite 21

2 EP 68 Gear Oil Page 2 of 4 6. ACCIDENTAL RELEASE MEASURES SPILLS OR LEAKS: Contain spills, advise EPA, st

Seite 22 - DRAWINGS

3 EP 68 Gear Oil Page 3 of 4 11. TOXICOLOGICAL INFORMATION – cont’d SEVERELY SOLVENT REFINED HEAVY PARAFFIN

Seite 23 - DRAWING # 000911

WARNING Please read thoroughly before installation, operation or maintenance of any Neptune pump EQUIPMENT MISUSE HAZARD Equipment misuse can cause

Seite 24 - PVC AND KYNAR HEAD OPTION

4 EP 68 Gear Oil Page 4 of 4 15. REGULATORY INFORMATION TSCA: This material complies with the TOXIC SUBS

Seite 25 - DOUBLE DIAPHRAGM OPTION

5 MATERIAL SAFETY DATA SHEET Page 1 of 4 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Seite 26

6 EP 90 Gear Oil Page 2 of 4 6. ACCIDENTAL RELEASE MEASURES SPILLS OR LEAKS: Contain spills, advise EPA,

Seite 27 - IRE FIGHTING MEASURES

7 EP 90 Gear Oil Page 3 of 4 11. TOXICOLOGICAL INFORMATION – cont’d SEVERELY SOLVENT REFINED HEAVY PARAF

Seite 28

8 EP 90 Gear Oil Page 4 of 4 15. REGULATORY INFORMATION TSCA: This material complies with the TOXIC SUBST

Seite 29 - 13. DISPOSAL INFORMATION

9 MAINTENANCE LOG Spare Parts Kit #____________________________________________________________ NEPTUNE CHEMICAL PUMP CO. Tel.: 215-699-8700

Seite 30 - 15. REGULATORY INFORMATION

10 © Copyright 2009 Neptune Chemical Pump Company, Printed in U.S.A

Seite 31

TABLE OF CONTENTS SECTION PARAGRAPH PAGE I — General Description 1 — Warranty 2 — Parts Ordering Instructions. 3 II — Ins

Seite 32

1 SECTION I GENERAL DESCRIPTION The Neptune Series 560 “dia-PUMP” is a reliable metering pump of the hydraulically actuated diaphragm type. Under con

Seite 33

2 LIMITED WARRANTY All Neptune Pumps are tested at the factory prior to shipment. Each part used in their construction has been carefully checked fo

Seite 34

3 PARTS ORDERING INSTRUCTIONS The complete model number and serial number of the pump must be furnished to insure prompt and accurate parts service.

Seite 35 - MAINTENANCE LOG

4 SECTION II INSTALLATION INSTRUCTIONS 1.0 GENERAL 1.0.1 When unpacking a pump or chemical feed system, be certain that no parts are thrown away.

Seite 36

5 1.0.9 (Continued) 1.0.11 Set capacity knob to zero and remove Air Bleed Plug from the top of Oil Chamber, refer to drawings 5